Skip to content
MATERIALS · 3 MIN ČÍTANIA · 10. 11. 2026

Roof underlay membrane: how to choose a breathable membrane and get it right.

SDOMVEA team
IN BRIEF What the membrane under the roofing does, when to choose a vapour-open one and where the vapour barrier belongs. Plus the most common installation mistakes.
Roof underlay membrane on a roof

You can’t see the underlay beneath the roofing, but if it is the wrong one or badly laid, it shows up as damp insulation or stains on the ceiling. Here is an overview of how to choose the membrane and what to watch out for when installing it.

What a roof underlay is for

No overlapping roof covering is completely watertight. In a storm with wind or with drifting snow, water gets under tiles or metal sheets, and condensation can also form under metal roofing. The underlay catches this water and carries it to the eaves, protects the insulation from wind and temporarily covers the roof during construction. How long the membrane may stay exposed depends on the UV resistance stated by the manufacturer.

Vapour-open membrane or vapour barrier?

These two membranes are often confused, but they do opposite jobs. A vapour-open (breathable) membrane goes above the thermal insulation, under the roofing: it keeps water from outside out but lets water vapour from the structure escape. A vapour barrier or vapour control layer goes on the inner, warm side of the insulation and stops moisture from the interior getting into the structure at all.

The rule is simple: towards the outside, the build-up must become increasingly open to water vapour. If you laid a vapour barrier under the roofing above the insulation, moisture would be trapped in the insulation.

How to choose the right membrane

  • Insulated roof – choose a highly vapour-open membrane that the manufacturer allows to be laid directly on the insulation or on boarding.
  • Metal roofing – on full boarding, membranes with a structured layer are also used; it separates the metal from the substrate and helps drain condensation.
  • Integrated adhesive tape – membranes with a self-adhesive edge speed up installation and the longitudinal joints are windtight without extra tape.
  • Technical data sheet – always compare vapour permeability (the Sd value), watertightness, strength and UV resistance using the manufacturer’s data.

Underlays with integrated tape, separating membranes for metal roofing and vapour barriers can be found in the category Membranes.

E-SHOP · 90 % IN STOCKOrder building materials onlineTimber, insulation, roofing and fasteners delivered to your site.To the e-shop →

Installation: overlaps and taping the joints

Lay the membrane horizontally, from the eaves upwards, so that each higher strip overlaps the one below and water runs over the surface, not into the joint. Keep the overlap stated in the manufacturer’s instructions; on many membranes it is marked in the print. Tape joints and connections with tape intended for that type of membrane and press it down with a roller.

On the rafters the membrane is secured by counter battens, which also create a ventilated gap under the roofing. Seal roof penetrations (chimney, vents, aerial) and connections to gables or walls with collars or tapes from the membrane manufacturer’s system.

Most common mistakes

  • A vapour barrier under the roofing instead of a vapour-open membrane – moisture stays in the insulation.
  • Laying from the top down – the upper strip ends up under the lower one and water runs straight into the joint.
  • Untaped joints and penetrations – that is exactly where wind and water find their way in.
  • Membrane ending short of the eaves – the water it catches should drain into the gutter, not onto the masonry or into the soffit.
  • Membrane left too long without roofing – UV resistance is limited; the manufacturer states for how long.
  • “All-purpose” tape – the adhesive must be suitable for the material of the membrane.

How much membrane to buy

Enter the area of the roof or walls and the number of rolls and adhesive tapes, including overlaps and connections, is calculated by the membrane configurator.

If you are doing the whole roof, the configurators for roof insulation and battens and counter battens will help too. Not sure what to choose? Write to us via the contact form.

Calculate your materials: Configurator: Membranes and airtightness · Configurator: Roof build-up · Configurator: Battens and counter-battens · Membranes

Was this article helpful?
Written by the DOMVEA teamBuilders from Namestovo. We build houses, log homes and roofs across Slovakia and Czechia.What we build →