TIMBER-FRAME WALL CONFIGURATOR

Timber-frame wall from stud to facade.

Enter the length and height of the external walls, openings and build-up. We calculate KVH studs with a cutting plan, insulation, STEICO and OSB boards and the vapour barrier – and show the wall's U-value right away.
✓ E-shop prices✓ Wall U-value✓ KVH cutting plan
1Wall dimensions
2Load-bearing frame and insulation
KVH studs (width × depth = insulation thickness)
Studs every 62.5 cm (board width), double studs and lintels at windows and doors. STEICO flex 036 wood-fibre insulation between the studs in stud depth.
More options
3External board / facade
4Inner side
Loading 3D preview…
Wall section and U-value
Wall area—
Wall thickness—
Wall U—
Price per m²—
Your materials
Total incl. VATapproximate, excl. delivery—
How we calculate
  • Area = length × height − windows and doors (door 2.2 m²).
  • Studs every 62,5 cm + 2 at each opening, corner and internal wall junction; sole plate, top plate and double top plate along the full length (stud height = wall height − 3 × KVH thickness); above openings a double lintel (clear width + 2 × stud; window square from its area, door 1,0 m), under windows a sill beam. KVH 13 m is cut with minimum waste – cutting list and plan are in the preview.
  • Insulation between studs = area × (1 − stud width / 62.5 cm), thickness by stud – we add the number of STEICO flex packs to the order.
  • Boards (STEICO and OSB): area + 6 % for cutting ÷ board area (for tongue and groove the manufacturer's cover area); vapour barrier area + 10 % for overlap ÷ roll area; OSB joints and connections to floor and ceiling are taped with Delta Multi Band.
  • Screws: TBS 2 at each end of a stud, lintel and sill (length = sole plate thickness + 60 mm), HBS for OSB approx. 12 pcs/m² (length ≥ board thickness + 35 mm).
  • U according to STN EN ISO 6946: the layer with studs is inhomogeneous – U from the average of the upper and lower limit of resistance; the timber fraction is calculated from the actual frame (studs, sole plates, top plates). λ of insulation and STEICO boards from the catalogue, timber and OSB 0,13 W/mK (STN EN ISO 10456). Requirements of STN 73 0540-2: U ≤ 0,22 (standard), 0,15 (recommended), 0,10 W/m²K (target).
  • Condensation: Glaser method in steady state (inside 20 °C / 50 %, outside −15 °C / 84 %), sd = μ × d from the catalogue or data sheet. U value and condensation are indicative – the thermal assessment is done by the designer.
  • Fixing of render boards and the render system are on request – number and type are set by the system manufacturer and the structural engineer.
  • A structural engineer checks statics and fire safety.